INTRODUCTION
In recent news, well-known factories have been fined RM50, 000 on each foreign worker due to overcrowded dormitories and unqualified requirements. This has sparked awareness among the industries and employers to review their workers’ accommodation to ensure it complies with the regulations.
For all workers’ accommodations built to comply with the regulations, industries must submit their workers’ accommodations design to the local authority. Some local authorities may even request the submission of the Temporary Development Order due to the integration of the residential elements in the industrial land. The approval of the local authority for workers’ accommodations is a part of the requirement of Jabatan Tenaga Kerja (JTK) to acquire the Accommodation Certificate.
If the workers are staying at a permanent building, the prerequisites to get the Accommodation Certificate is to have a Certificate of Completion and Compliance (CCC) for the building. Since most workers’ quarters are cabin or modular type of accommodations, it would have been classified as a temporary building. Therefore, the prerequisite is to have a Temporary Building Permit before getting the Accommodation Certificate [1]. A Temporary Building Permit issued by the local authority is intended to allow temporary buildings to exist only for a period of time. The permit duration will be dependent on the condition imposed by the local authority. For this Temporary Building Permit, only the relevant local departments such as the Local Authority Building Department and Local Authority Engineering Department will be involved, while external departments such as Firefighting Department from each state (Jabatan Bomba dan Penyelamat Negeri) may get involved if necessary.
REGULATION GUIDELINES
What are the other elements required from the regulations provided by the guidelines?
Employees’ Minimum Standards of Housing, Accommodations and Amenities (Accommodation and Centralized Accommodation) Regulations 2020
- Separate accommodations for the employees of the opposite sex shall be provided.
- Sleeping area with a floor area not less than 3m2 per employee shall be provided.
- Shared spaces consist of the rest area, kitchen, living room, and 1 bathroom and toilet (whether separated or together) per 15 employees.
- Sufficient first aid kits and fire extinguishers must be installed.
- Provide gas stove, dustbin, clean water supply & electricity supply.
- Fan for each rest area, dining area and sleeping area.
- Lamp for each rest area, dining area, sleeping area, kitchen area, bathroom and toilet.
- One area to hang out clothes.
Reference: http://jtksm.mohr.gov.my/images/akta446/9_Penginapanberpusat.pdf
Guidelines for Setting the Minimum Standards for the Accommodation of Foreign Workers 2018
- Separate accommodations for the employees of the opposite sex shall be provided.
- The area of enclosed space for a worker should be 4.5m2; or the sleeping area shall not less than 3m2.
- One toilet and one bathroom shall be provided for every 15 workers; or one toilet and one separate bathroom with a urinal should be provided for every 25 workers.
- Living spaces such as kitchen, bathroom, toilet, and other commonly used areas shall remain to use as their original purpose and shall not be changed.
- Have adequate ventilation and natural light according to By-Law 39, Uniform Building By-Laws 1984.
- Sufficient first aid kits and fire extinguishers must be installed.
- Provide gas stove, dustbin, clean water supply & electricity supply.
- Provide a bed, mattress, pillow, and wardrobe.
AN EXAMPLE OF A SUITABLE LAYOUT
As shown in Figure 1, the example floor plan has 4 workers quarters, where each of them has an area of 21 square meters. The suitable number of workers that can stay in one room is calculated as follows:
?????? ?? ??????? ??????? ?? ??? ????=???? ?? ????/3 (??? ???????????)[1]
?????? ?? ??????? ??????? ?? ??? ????=21/3
?????? ?? ??????? ??????? ?? ??? ????=7 (???????)
Since there are 4 workers quarters, the total number of workers staying under one roof would be 7×4 which is 28 workers.
In Figure 1, two toilets have been provided, where the toilets shown here have integrated bathroom facilities as well. Following Act 446 [1], every 15 workers should have been provided with 1 toilet, therefore there will be a maximum of 30 workers for the usage of the 2 toilets, which is sufficient for the 28 workers estimated.
The kitchen and dining area have been provided as well, while the garbage disposal area is located outside of the building, which is not shown in Figure 1. Finally, first aid kits and fire extinguishers should be installed near the exits and other locations to cover the whole building.
Important notes of workers’ accommodation:
i. All facilities and space shall be used for the original intended purpose only, and it cannot be modified [3].
ii. Any changes related to the occupancy capacity will need to obtain new approval from local authorities [3].
CONCLUSION
These requirements are vital to ensure the well-being of the foreign workers staying in these accommodations as well. Hence, to ensure well-designed workers’ accommodations that comply with the regulations, employers should seek professional advice from qualified architects and engineers to avoid unnecessary fines.